Exide LKVA Home UPS can be customized to suit your need and budget. Key in the specifics and pick the right Home UPS from the Exide Home Inverter range.
Click Here| Description | GQP 12V 650VA | GQP 12V 850VA | GQP 12V 1050VA | GQP 24V 1450VA | GQP 12V 1450VA |
|---|---|---|---|---|---|
| Output Voltage at No Load | 220V ± 7V AC | ||||
| Output Frequency | 50Hz ± 1Hz | ||||
| Output Wave Form | Pure Sine Wave | ||||
| Nominal Battery Voltage | 12V DC | 24V DC | 12V DC | ||
| Battery Low Cut Off | 10.5V ± 0.2V DC | 21.0V ± 0.4V DC | 10.5V ± 0.2V DC | ||
| Model | GQP 12V 650VA | GQP 12V 850VA | GQP 12V 1050VA | GQP 24V 1450VA | GQP 12V 1450VA |
|---|---|---|---|---|---|
| Maximum Charging Current (NC) | 09Amp ± 1Amp | 09Amp ± 1Amp | 09Amp ± 1Amp | 09Amp ± 1Amp | 22Amp ± 10% |
| Maximum Charging Current (EC) | 11Amp ± 1Amp | NA | |||
| Maximum Charging Current (HC) | 13Amp ± 1Amp | 30Amp ± 10% | |||
| Boost Charging Voltage | 14.4V ± 0.2V DC | 28.8V ± 0.4V DC | 14.4V ± 0.2V DC | ||
| Trickle Charging Voltage | 13.7V ± 0.2V DC | 27.4V ± 0.4V DC | 13.7V ± 0.2V DC | ||
| Change Over Time Mains to Back-up (@ UPS Mode) | ≤ 10 msec | ||||
| Change Over Time Back-up to Mains (@ UPS Mode) | ≤ 10 msec | ||||
| Input Voltage Range (@ UPS Mode) | 180V - 260V ± 10V AC | ||||
| Change Over Time Mains to Back-up (@ Normal Mode) | ≤ 40 msec | ||||
| Change Over Time Back-up to Mains (@ Normal Mode) | ≤ 10 msec | ||||
| Input Voltage Range (@ Normal Mode) | 100V - 280V ± 10V AC | ||||
*Not Applicable for GQP 12V 1450VA