In accordance with the Government of India, Ministry of Environment and Forests' notification on Batteries (Management & Handling) Rules, 2001, it is the responsibility of every consumer to ensure that used Lead- Acid Batteries are not disposed off in any manner other than returning to Dealer for recycling of hazardous lead content. Please contact your Dealer for trade-in purpose.

Note: Clause 10. Responsibilities of consumer or bulk customer:

shall be the responsibility of the consumer to ensure that used batteries are not disposed of in any manner other than depositing with the dealer, manufacturer, importer, assembler, registered recycler, re-conditioner or at the designated collection centres.

Table 1 (Terms of Warranty)

Battery Type Warranty In Months
6LMS20 36
6SBZ40
6LMS40
6LMS60
6LMS75
6LMS100
6LMS120
6LMS150
6LMS180
6LMS200
6LMS20L 60
6SBZ40L
6LMS40L
6LMS60L
6LMS75L
6LMS100L
6LMS120L
6LMS150L
6LMS180L
6LMS200L
6SBZ105L

Table 2 (Recommended Parameters for ambient temperature of 25°C-30°C)

Charging Current Maximum - 20% of the battery Ah capacity
Minimum - 10% of the battery AH capacity
Bulk Voltage 2.60 +/- 0.02V x no. of cells
Float Voltage 2.30 +/- 0.02V x no. of cells
Load Reconnect Voltage 2.16 +/- 0.02V x no. of cells
Low Voltage Disconnect 1.90 +/- 0.02V x no. of cells
Recharge Factor 110% of discharge Ah
Temperature Correction
Factor (reference 25ºC)
Float: -3mV/°C/2V unit